User`s manual

3-4 Intellio C218Turbo User's Manual
Setting” dialog box to change the port COM number mappings.
You have to set up all the ports of the board with the desired “COM number”,
which should not conflict with other COM number in use. In this “Individual Port
Setting” dialog box, you may have two ways to map the physical ports to COM
numbers depending on the check box “Auto Enumerating COM number”.
Sequential Port Mapping: (Enable “Auto Enumerating COM number”)
Specify the COM number of the first port and subsequent ports are mapped
to continuous COM numbers. For instance, if first port is mapped to
COM10, then second port is mapped to COM11 sequentially.
Non-sequential Port Mapping: (Disable “Auto Enumerating COM
number”) Specify the COM number for individual port. For instance, the
second port can be out of sequence, say COM18, while the first port is
mapped to COM10.
In “Individual Port Setting” dialog, you may click on [Advanced Setting] button
to tune the advanced features, “UART FIFO” and “Transmission Mode”, for
each port for particular performance requirements.