User`s manual
Moxa Managed Ethernet Switch/Extender  Featured Functions 
3-5 
Port Settings 
Ethernet Port Settings 
Port settings are included to give the user control over port access, port transmission speed, flow control, and 
port type (MDI or MDIX). 
Enable 
Setting  Description  Factory Default 
Checked  Allows data transmission through the port.  Enabled 
Unchecked  Immediately shuts off port access. 
ATTENTION 
If a connected device or sub
-network is wreaking havoc on the rest of the network, the Disable 
option under 
Advanced Settings/Port 
gives the administrator a quick way to shut off access through this port 
immediately.
Description 
Setting  Description  Factory Default 
Media type  Displays the media type for each module’s port  N/A 
Name 
Setting  Description  Factory Default 
Max. 63 characters  Specifies an alias for the port to help administrators 
differentiate between different ports. Example: PLC 1 
None 
Speed 
Setting  Description  Factory Default 
Auto 
Allows the port to use the IEEE 802.3u protocol to negotiate 
with connected devices. The port and connected devices will 
determine the best speed for that connection. 
Auto 
1G-Full 
Choose one of these fixed speed options if the connected 
Ethernet device has trouble auto-negotiating for line speed. 
100M-Full 
100M-Half 
10M-Full 
10M-Half 