User`s manual
Moxa Managed Ethernet Switch/Extender  Featured Functions 
3-63 
802.1X 
Setting  Description  Factory Default 
Enable/Disable  Checkmark the checkbox under the 802.1X column to enable 
IEEE 802.1X for one or more ports. All end stations must enter 
usernames and passwords before access to these ports is 
allowed. 
Disable 
802.1X Re-Authentication 
The Moxa switch can force connected devices to be re-authorized manually. 
802.1X Re-Authentication 
Setting  Description  Factory Default 
Enable/Disable  Enables or disables 802.1X Re-Authentication  Disable 
Local User Database Setup 
When setting the Local User Database as the authentication database, set the database first. 
Local User Database Setup 
Setting  Description  Factory Default 
User Name 
(Max. of 30 characters)
User Name for the Local User Database  None 
Password 
(Max. of 16 characters)
Password for the Local User Database  None 
Description 
(Max. of 30 characters)
Description for the Local User Database  None 
NOTE
The user name for the Local User Database is case
-insensitive. 