Wiring the Redundant Power Inputs
The top two pairs of contacts of the 10-contact terminal block
connector on the AWK-1137C’s top panel are used for the AWK-1137C’s
two DC inputs. Top and front views of the terminal block connector are
shown below:
STEP 1:
Insert the negative/positive DC wires into
the V-/V+ terminals.
STEP 2:
To keep the DC wires from pulling loose, use a
small flat-blade screwdriver to tighten the
wire-clamp screws on the front of the terminal
block connector.
STEP 3:
Insert the plastic terminal block connector
prongs into the terminal block receptor, which
is located on the AWK-1137C’s side panel.
NOTE Input Terminal Block (CN1) is suitable for wire size range of
12-28 AWG (3.31-0.0804 mm²) and a torque value of 4.5 lb-
in (0.51 Nm)
ATTENTION
If the AWK-1137C is connected to a motor or other similar type
of equipment, be sure to use power isolation protection. Before
connecting the AWK-1137C to the DC power inputs, make sure
the DC power source voltage is stable.
Using the Reset Button
The Reset button is used to load the factory default settings. Use a
pointed object to hold the Reset button down for five seconds to load
the factory defaults.
Activating AeroMag Function
Push the Reset Button 5 times to activate AeroMag. To deactivate it
again, push the Reset Button 3 times.