User's Manual

AirWorks AWK-4121 User’s Manual Getting Started
First-time Installation and Configuration
Before installing the AWK-4121, make sure all items in the Package Checklist are in the box. In
addition, you will need access to a notebook computer or PC equipped with an Ethernet port. The
AWK-4121 has a default IP address that you must use when connecting to the device for the first
time.
Step 1: Select the power source.
The AWK-4121 can be powered by DC power input or PoE (Power over Ethernet). The
AWK-4121 will use whichever power source you choose.
Step 2: Connect the AWK-4121 to a notebook or PC.
Since the AWK-4121 supports MDI/MDI-X auto-sensing, you can use either a straight-through
cable or crossover cable to connect the AWK-4121 to a computer. If the LED indicator on
AWK-4121’s LAN port lights up, it means the connection is established.
Step 3: Set up the computer’s IP address.
Set an IP address on the same subnet as the AWK-4121. Since the AWK-4121’s default IP address
is 192.168.127.253, and the subnet mask is 255.255.255.0, you should set the IP address of the
computer to 192.168.127.xxx.
NOTE
After you select Maintenance Load Factory Default and click the Submit button, the
AWK-4121 will be reset to factory default settings and the IP address will be also reset to
192.168.127.253.
Step 4: Use the web-based manager to configure AWK-4121
Open your computer’s web browser and type http://192.168.127.253 in the address field to access
the homepage of the web-based Network Manager. Before the homepage opens, you will need to
enter the user name and password as shown in the following figure. For first-time configuration,
enter the default user name and password and then click on the Login button:
2-2