User's Manual

AirWorks AWK-4121 User’s Manual Web Console Configuration
Network Settings
The Network Settings configuration allows you to modify the usual TCP/IP network parameters.
An explanation of each configuration item is given below.
IP configuration
Setting Description Factory Default
DHCP The AWK-4121’s IP address will be
assigned automatically by the
network’s DHCP server
Static Set up the AWK-4121’s IP address
manually.
Static
IP address
Setting Description Factory Default
AWK-4121’s IP address Identifies the AWK-4121 on a TCP/IP
network.
192.168.127.253
Subnet mask
Setting Description Factory Default
AWK-4121’s subnet
mask
Identifies the type of network to
which the AWK-4121 is connected
(e.g., 255.255.0.0 for a Class B
network, or 255.255.255.0 for a Class
C network).
255.255.255.0
Gateway
Setting Description Factory Default
AWK-4121’s default
gateway
The IP address of the router that
connects the LAN to an outside
network.
None
NOTE
A warning message will be shown once to remind you to set up the default gateway if the
Gateway is not set in Client mode. It is not necessary to set up a default gateway for the
AWK-4121 if you only plan to establish a local network, and no packet goes to an outside
network.
3-6