AirWorks AWK-4121 User’s Manual Web Console Configuration
Start IP address
Setting Description Factory Default
IP address Indicates the IP address which
AWK-4121 can start assigning
None
Maximum number of users
Setting Description Factory Default
1 – 999 Specifies how many IP address can be
assigned continuously
None
Client lease time
Setting Description Factory Default
1 – 10 days The lease time for which an IP
address is assigned. The IP address
may go expired after the lease time is
reached.
10 (days)
Packet Filters
The AWK-4121 includes various filters for IP-based packets going through LAN and WLAN
interfaces. You can set these filters as a firewall to help enhance network security.
MAC Filter
The AWK-4121’s MAC filter is a policy-based filter that can allow or filter out IP-based packets
with specified MAC addresses. The AWK-4121 provides 8 entities for setting MAC addresses in
your filtering policy. Remember to check the Active check box for each entity to activate the
setting.
Enable
Setting Description Factory Default
Enable Enables MAC filter
Disable Disables MAC filter
Disable
Policy
Setting Description Factory Default
Accept Only the packets fitting the entities on
list can be allowed.
Drop Any packet fitting the entities on list
will be denied.
Drop