AirWorks AWK-5222 User’s Manual Web Console Configuration
3-8
Query period
Setting Description Factory Default
Query period time
(1- 9999 seconds)
This parameter determines how often
the time is updated from the NTP
server.
600 (seconds)
Wireless Settings
The essential settings for wireless networks are presented in this function group. Settings must be
properly set before establishing your wireless network.
Operation Mode
The AWK-5222 supports three operation modes that are used for different wireless network
applications:
Wireless Redundancy
The wireless redundancy operation mode can be used to set up a redundant wireless connection
between a redundant client device and a redundant AP device. The redundant structure involves
using the AWK-5222’s two RF modules to set up two independent wireless connections between
the redundant client and redundant AP devices. If either of the two wireless connections fails, the
other wireless connection will continue transmitting packets between the redundant client and
redundant AP devices. In fact, one of the biggest advantages of the AWK-5222’s wireless
redundancy mode is that you can expect “zero data loss.”