User's Manual

Table Of Contents
AirWorks AWK-5222 User’s Manual Web Console Configuration
3-35
Admin auth type (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
No Auth Use admin account to access objects.
No authentication
MD5 Provide authentication based on the
HMAC-MD5 algorithms. 8-character
passwords are the minimum
requirement for authentication.
SHA Provides authentication based on
HMAC-SHA algorithms. 8-character
passwords are the minimum
requirement for authentication.
No Auth
Admin private key (for V1, V2c, V3, and V3 only)
Setting Description Factory Default
Disable No data encryption
DES DES-based data encryption
AES AES-based data encryption
Disable
Private key
A data encryption key is the minimum requirement for data encryption (maximum of 63
characters)
Private MIB Information Device Object ID
Also know as OID. This is the AWK-5222’s enterprise value. It is fixed.
Storm Protection
In general, one host should not be allowed to occupy unlimited bandwidth, particularly when the
device malfunctions. For example, so-called “broadcast storms” could be caused by an incorrectly
configured topology or a malfunctioning device. TheAWK-5222 not only prevents broadcast
storms, but can also be configured to a different ingress rate for all packets, giving administrators
full control of their limited bandwidth to prevent undesirable effects caused by unpredictable
faults.
Setting Description Factory Default
Enable or disable the Broadcast
Storm Protection for multicast packet
globally
Enable/Disable
Enable or disable the Broadcast
Storm Protection for unknown
multicast and unknown unicast
packets globally.
Enable (for unknown
multicast and unknown
unicast packet)