User's Manual

Table Of Contents
AirWorks AWK-5222 User’s Manual Web Console Configuration
3-50
Misc. Settings
Additional settings to help you manage your AWK-5222, are available on this page.
Reset button
Setting Description Factory Default
Always enable The AWK-5222’s Reset button works
normally.
Disable after 60 sec The AWK-5222’s Reset button will
become invalid 60 seconds after the
AWK-5222 completes booting.
Always enable
Save Configuration
The following figure shows how the AWK-5222 stores the setting changes into volatile and
non-volatile memory. All data stored in volatile memory will disappear when the AWK-5222 is
shutdown or rebooted unless they are y. Because the AWK-5222 starts up and initializes with the
settings stored in flash memory, all new changes must be saved to flash memory before restarting
the AWK-5222.
This also means the new changes will not work unless you run either the Save Configuration
function or the Restart function.
After you click on Save Configuration in the left menu box, the following screen will appear.
Click Save if you wish to update the configuration settings in the flash memory at this time.
Alternatively, you may choose to run other functions and put off saving the configuration until
later. However, the new setting changes will remain in the non-volatile memory until you save the
configurations.