AirWorks AWK-5222 User’s Manual Introduction
1-4
Interface
Default Antenna 2dBi dual-band, Omni-directional antenna
Antenna Connector RP-SMA (male)
Connection 10-pin Removable Terminal Block
Alarm Contact 1 relay output (capacity: 1A @24VDC)
Digital Input 2 electrically-isolated inputs
‧ +3 to -30V for state “0” (OFF)
‧ 13 to 30V for state “1” (ON)
‧ Max. input current: 8 mA
Console RS-232 (RJ45 type)
LAN Port 10/100BaseT(X) auto negotiation speed
LED Indicators PWR1, PWR2, PoE, FAULT, STATE, Signal Strength, CLIENT
MODE, BRIDGE MODE, WLAN, 10M, 100M
Power
Input Voltage 12 to 48 VDC, redundant dual DC power inputs or 48 VDC
Power-over-Ethernet (IEEE 802.3af)
Input Current 0.494 to 0.121 A (@ 12 to 48 VDC)
Input Current (@ 24VDC) 0.3 A
Overload Current Protection 1.6 A
Reverse Polarity Protection Present
Mechanical
Dimensions 62.05 x 135 x 105 mm (2.44 x 5.31 x 4.13 in)
Weight 880 g
Installation DIN-rail, or Wall Mounting (with optional wall mounting kit)
Casing IP30 protection, aluminum case
Environment
Operating Temperature: Standard models: 0 to 60°C (32 to 140°F)
Wide Temp Models: -40 to 75°C (-40 to 167°F)
Storage Temperature: -40 to 85ºC (-40 to 185ºF)
Ambient Relative Humidity 5 to 95% (non-condensing)
Regulatory Approvals*
Safety: EN60950-1, UL60950-1
EMC: EN301 489-1/-17, FCC Part 15, EN55022/55024, IEC61000-6-2/-4
Environmental/EMC
compliancy
EN50155, EN50121-1/-4
*Please check Moxa’s website for the most up-to-date certification status.
Warranty
5 years
Details: See http://
www.moxa.com/warranty
ATTENTION
The AWK-5222 is NOT a portable mobile device and should be located at least 20cm away from
the human body. The AWK-5222 is NOT designed for the general public. To deploy AWK-5222s
and establish a wireless network safely, a well-trained technician is required for installation.
800mA (@ 12 to 48 VDC)