User's Manual

AirWorks AWK-3121 User’s Manual Web Console Configuration
Transmission Power
Setting Description Factory Default
Auto
Specifies wireless signal coverage by
automatically selecting the strength o
f
Tx power
Full
Equivalent to 100% of maximum Tx
power
High
Equivalent to 75% of maximum Tx
power
Medium
Equivalent to 50% of maximum Tx
power
Low
Equivalent to 25% of maximum Tx
power
Full
Beacon Interval (for AP mode only)
Setting Description Factory Default
Beacon Interval
(40-1000 ms)
This value indicates the frequency
interval of the beacon
100 (ms)
DTIM Interval (for AP mode only)
Setting Description Factory Default
Data Beacon Rate
(1-16384)
This value indicates how often the
AWK-3121 sends out a Delivery
Traffic Indication Message
1
Fragment threshold
Setting Description Factory Default
Fragment Length
(256-2346)
This parameter specifies the
maximum size a data packet before
splitting and creating another new
packet
2346
RTS threshold
Setting Description Factory Default
RTS/CTS Threshold
(256-2346)
This setting determines how large a
packet can be before the Access Point
coordinates transmission and
reception to ensure efficient
communication
2346
NOTE
You can refer to the related glossaries in Chapter 5 for more detailed information about the
above-mentioned settings. By setting these parameters properly, you can better tune the
performance of your wireless network.
3-20