User's Manual
AirWorks AWK-3121 User’s Manual Web Console Configuration
SNMP security modes and security levels supported by the AWK-3121 are shown in the following
table. Select the security mode and level that will be used to communicate between the SNMP
agent and manager.
Protocol
Version
Setting on
UI web page
Authentication
Type
Data
Encryption
Method
V1, V2c
Read
Community
Community
string
No Use a community string match for
authentication
SNMP
V1, V2c
V1, V2c
Write/Read
Community
Community
string
No Use a community string match for
authentication
No-Auth No
No
Use account with admin or user to access
objects
MD5 or SHA Authentication
based on MD5
or SHA
No Provides authentication based on
HMAC-MD5, or HMAC-SHA algorithms.
8-character passwords are the minimum
requirement for authentication.
SNMP V3
MD5 or SHA Authentication
based on MD5
or SHA
Data
encryption
key
Provides authentication based on
HMAC-MD5 or HMAC-SHA algorithms,
and data encryption key. 8-character
passwords and a data encryption key are the
minimum requirements for authentication
and encryption.
The following parameters can be configured on the SNMP Agent page. A more detailed
explanation of each parameter is given below the following figure.
Enable
Setting Description Factory Default
Enable Enables SNMP Agent
Disable Disables SNMP Agent
Disable
Read community (for V1, V2c)
Setting Description Factory Default
V1, V2c Read
Community
Use a community string match with a
maximum of 31 characters for
authentication. This means that the
SNMP agent can access all objects
with read-only permissions using this
community string.
public
3-29