System Log
System Log Event Types
Detail information for grouped events is shown in the following table. You can check the box for
Enable log to enable the grouped events. All default values are enabled (checked). The log for
system events can be seen in Status > System Log.
System-related events Event is triggered when…
System restart (warm start)
The AWK-3121 is rebooted, such as when its settings
are changed (IP address, subnet mask, etc.).
Network-related events Event is triggered when…
LAN link on The LAN port is connected to a device or network.
LAN link off
The port is disconnected (e.g., the cable is pulled out,
or the opposing device shuts down).
Client joined/ left
(for AP mode)
A wireless client is associated or disassociated.
WLAN connected to AP
(for Client mode)
The AWK-3121 is associated with an AP.
WLAN disconnected
(for Client mode)
The AWK-3121 is disassociated from an AP.
Config-related events Event is triggered when…
Configuration Changed A configuration item has been changed.
Configuration file import via Web
Console
The configuration file is imported to the AWK-3121.
Console authentication failure An incorrect password is entered.
Firmware upgraded The AWK-3121’s firmware is updated.
Power events Event is triggered when…
Power 1/2 transition (On -> Off) The AWK-3121 is powered down in PWR1/2.
PoE transition (On -> Off) The AWK-3121 is powered down in PoE.
Power 1/2 transition (Off -> On) The AWK-3121 is powered via PWR1/2.
PoE transition (Off -> On) The AWK-3121 is powered via PoE.
DI events Event is triggered when…
DI1/2 transition (On -> Off) Digital Input 1/2 is triggered by on to off transition
DI1/2 transition (Off -> On) Digital Input 1/2 is triggered by off to on transition