User's Manual

AirWorks AWK-3121 User’s Manual Web Console Configuration
User name & Password
Setting Description Factory Default
User name and password used in the
SMTP server
None
From e-mail address
Setting Description Factory Default
Max. 63 characters Enter the administrators e-mail
address which will be shown in the
“From” field of a warning e-mail.
None
To E-mail address 1/ 2/ 3/ 4
Setting Description Factory Default
Max. 63 characters Enter the receivers’ e-mail addresses. None
Relay
The AWK-3121 has one relay output, which consists of 2 terminal block contacts on the
AWK-3121’s top panel. These relay contacts are used to indicate user-configured events and
system failure.
The two wires attached to the relay contacts form an open circuit when a user-configured event is
triggered. If a user-configured event does not occur, the relay circuit will remain closed. For safety
reasons, the relay circuit is kept open when the AWK-3121 is not powered.
Relay Event Types
You can check the box for Active to enable the event items. All default values are deactivated
(unchecked). Details for each event item can be found in the “System log Event Types” table on
page 3-31.
3-34