EU Countries Intended for Use
The ETSI version of this device is intended for home and office use in Austria, Belgium, Denmark,
Finland, France (with Frequency channel restrictions), Germany, Greece, Ireland, Italy,
Luxembourg, Portugal, Spain, Sweden, The Netherlands, and United Kingdom.
The ETSI version of this device is also authorized for use in EFTA member states Norway and
Switzerland.
EU Countries Not Intended for Use
None.
Potential Restrictive Use
France: only channels 10, 11, 12, and 13.
Firmware Recovery
When the LEDs of FAULT, Signal Strength, CLIENT, BRIDGE and WLAN all light up
simultaneously and blink at one-second interval, it means the system booting has failed. It may
result from some wrong operation or uncontrollable issues, such as an unexpected shutdown
during firmware update. The AWK-3121 is designed to help administrators recover such damage
and resume system operation rapidly. You can refer to the following instructions to recover the
firmware:
Connect to the AWK-3121s ES-232 console with 115200bps and N-8-1. You will see the
following message shown on the terminal emulator every one second.
Press Ctrl - C and the following message will appear.
Enter 2 to change the network setting. Specify where the AWK-3121’s firmware file on the TFTP
server and press y to write the settings into flash memory.