User`s manual
2-2 Industio CI-132 Series User’s Manual
If the default settings above are what you desired and good for the system
without conflicts, you may simply install the board in the system and go directly
to the next chapter, “Software Installation”. Otherwise, follow the instructions
below.
In addition to the normal hardware installation (detailed in the later section,
“Hardware Installation with IO-IRQ Utility”), a quick hardware installation (detailed
right in the next section, “Quick Hardware Installation without IO-IRQ Utility”) is
provided for you to facilitate the hardware installation, only under the circumstances
that:
u Only one Industio CI-132 Series board is allowed to install in a system.
u Windows NT and 95/98 are the only operating systems supported.
u CAP Jumper JP1 is short and I/O address 0xA700 must be free.
First Thing to Do: Interface Settings
Before installing the board into the slot, you should set all the jumpers and switches to
what you want.
CAP Jumper JP1:
Open Not forcing the CAP address to 0xA700.
Short Force the CAP address to 0xA700. Set to this if you want
to do quick hardware installation.
Or forget the CAP
address when you want to reconfigure the board with IO-
IRQ.
Interface Switch SW2 for Port 1/Port 2:
ON Set the port interface to RS-485.
OFF Set the port interface to RS-422.
Data Mode Switch SW1 for Port 1/Port 2: (Valid when SW2 is set to ON)
ON Set the RS-485 port to Automatic Data Direction Control
Mode.
OFF Set the RS-485 port to By RTS Mode.
Termination Resistor Port 1 Jumper JP3: (Valid when SW2 is set to ON)
Open Not using Termination Resistor
Short Using Termination Resistor
Termination Resistor Port 1 Jumper JP4: (Valid when SW2 is set to ON)
Open Not using Termination Resistor
Short Using Termination Resistor