User`s manual
Hardware Installation
Industio CI-132 Series User’s Manual 2-5
+ If you are installing multiple boards, insert one board at a time and
configure it using the Io-irq program before inserting the next board.
This is to prevent conflict between two boards with same default
hardware settings.
The
Industio CI-132 Series has the following default (factory) settings,
I/O address :
0x180 (1st port), 0x188 (2nd port)
IRQ :
10
INT Vector : 0x1C0
Configuration Access Port (CAP) : 0x180
4.
Power on the PC and enter into DOS system.
5. Run the utility “Io-irq.exe” contained in the driver diskette to set up I/O address,
IRQ and INT vector of the board. Please refer to the next section, “IO-IRQ Utility
and Hardware Configuration” for more details. Or follow the on-line help to
configure the
Industio CI-132 Series board.
After completing the hardware configuration, the board is ready for use under
operating systems, such as Windows NT and 95/98, DOS, etc.
IO-IRQ Utility and Hardware Configuration
Note that the CAP address, e.g. 0x180, is identical to the first port's I/O address
except in one case that the JP1 jumper is installed before powering on the PC. In this
case, the CAP address will be forced to
0xA700. The CAP address must be typed
correctly. With the correct CAP address, the utility can find the configuration stored
in the
on-board EEPROM and display it on the configuration panel. The CAP
address is the only channel via which the configuration utility Io-irq.exe can access
the board.
1. Run the utility “Io-irq.exe” contained in the driver diskette to set up I/O address,
IRQ and INT vector of the board.