User`s manual
Software Installation
Industio CI-132 Series User’s Manual 3-3
5. Select “MOXA Smartio/Industio Family multiport board” in the “Select
OEM Option” dialog box, and then click [
OK] to enter the “MOXA
Configuration Panel
” dialog box to start the installation.
6. In the “MOXA Configuration Panel” dialog box, click [Add] to enter
“
Property” dialog box to add the Industio CI-132 Series board. Select the “CI-
132 Series
” in the “Board Type” field. If necessary, type the desired interrupt
vector address in the “INT Vector” field, and the desired I/O port address in the
"Base I/O Port Address" field. Then select the desired interrupt number in the