User`s manual

Industrial Secure Router User's Manual EDR-810 Series Features and Functions
3-37
NOTE
1.
The DHCP Server is only available for LAN interfaces.
2. The Pool
First/Last IP Address must be in the same Subnet on the LAN.
Static DHCP
Use the Static DHCP list to ensure that devices connected to the Industrial Secure Router always use the same IP
address. The static DHCP list matches IP addresses to MAC addresses.
In the above example, a device named “Device-01” was added to the Static DHCP list, with a static IP address set
to 192.168.127.101 and MAC address set to 00:09:ad:00:aa:01. When a device with a MAC address of
00:09:ad:00:aa:01 is connected to the Industrial Secure Router, the Industrial Secure Router will offer the IP
address 192.168.127.101 to this device.
Static DHCP Enable/Disable
Setting Description Factory Default
Enable/Disable Enable or disable Static DHCP server function Disable
Name
Setting Description Factory Default
Max. 30 characters The name of the selected device in the Static DHCP list None
MAC Address
Setting Description Factory Default
MAC Address
The MAC address of the selected device
None
Static IP
Setting Description Factory Default
IP Address The IP address of the selected device None
Netmask
Setting Description Factory Default
Netmask The netmask for the selected device 0.0.0.0
Lease Time
Setting Description Factory Default
5min. The lease time of the selected device None
Default Gateway
Setting Description Factory Default
IP Address The default gateway for the selected device 0.0.0.0