User Manual

- 9 -
STEP 3:
Once the screws are fixed on the
wall, insert the four screw heads
through the large parts of the
keyhole
-shaped apertures, and
then slide
the EDS-205A/208A
downwards
, as indicated. Tighten
the four screws for
added stability.
ATEX and IECEx Information
1. Certificate number
ATEX: DEMKO 10 ATEX 0909900X
IECEx: IECEx UL 14. 0085X (For EDS-205A Series only)
2. Ambient range
-40°C ≤ Tamb ≤ 75°C for Models with suffix of “-T”
-10°C ≤ Tamb ≤ 60°C for Models without suffix of “-T”
3. Certification string:
ATEX: Ex nA IIC T4 Gc
IECEx: Ex nA IIC T4 Gc (For EDS-205A Series only)
4. Standards covered
EN 60079-0:2012/A11:2013/IEC 60079-0:2011 Ed.6
EN 60079-15:2010/IEC 60079-15:2010 Ed.4 (For EDS-205A
Series only)
5. The conditions of safe usage:
Subject devices are to be installed in an ATEX certified IP54
enclosure accessible only with use of a tool and used in an
area of not more than pollution degree 2 as defined by EN
60664-1.
Provisions shall be made to provide the transient protection
device to be set at a level not exceeding 140% of the peak
rated voltage.
Subject devices must use conductors suitable for use at an
ambient temperature of 100°C and must be suitable for the
Power Supply Terminal.
NOTE
Suitable for use in Class I, Division 2, Groups A, B, C and D
hazardous locations, or nonhazardous locations only.
WARNING
EXPLOSION HAZARD
- Do not disconnect equipment while the
circuit is live or unless the area is known to be free of ignitable
concentrations.