STEP 3:
Once the screws are fixed in the
wall, insert the four screw heads
through the large parts of the
keyhole
-shaped apertures, and
then slide EDS
-308/309
downwards, as indicated. Tighten
the four screws for added
stability.
ATEX Information
1. Certificate number DEMKO 08 ATEX 0717913X
2. Ambient range: -40°C Tamb 75°C
3. Certification string: Ex nA nC IIC T4 Gc
4. Standards covered:
EN 60079-0:2012+A11:2013 / IEC 60079-0 Ed.6 , EN
60079-15:2010 / IEC 60079-15 Ed.45.
5. The conditions of safe usage:
These products must be mounted in an IP54 enclosure.
Install in an area of pollution degree 2 or less.
Provisions shall be made either in the equipment or external to
the equipment to provide the transient protection device to be
set at a level not exceeding 140% of the peak rated voltage.
A 4 mm conductor must be used when a connection to an
external grounding screw is utilized.
Supply Terminal Block (JP2) Cat. No. 5EHDR-06P mating with
Cat. No. 5ESDV-06P, manufactured by Dinkle Enterprise Co.,
Ltd. Rated 300 V, 15 A, suitable for 0.8-3.31 mm² (28-12 AWG)
wire size, torque value 0.51 N-m (4.5 lb-in). The Terminal
Block(J1) is suitable for 28-12 AWG (0.0804-3.31 mm²). The
input terminal cable size 14 AWG( 2.1 mm²).
Conductors suitable for use in an ambient temperature of 101°C
must be used for the Power Supply Terminal. Provisions must be
made to prevent the rated voltage being exceeded by transient
disturbances of more than 40%.
WARNING
EXPLOSION HAZARD
Do not disconnect equipment unless
power has been removed or the area is known to be
non-hazardous.