ATTENTION
• Conductors suitable for use in an ambient temperature of 93°C
must be used for the power supply
terminal.
• One individual conductor in a clamping point with 28
-
12 AWG
wire size, and a torque value of 4.5 lb-in should be used.
ATTENTION
Transient provisions shall be provided to limit the peak rated
voltage to a maximum of 140% of the peak rated voltage.
Communication Connections
EDS-316 models have 14, 15, or 16 10/100BaseT(X) Ethernet ports, and
2, 1, or 0 (zero) 100BaseFX (SC/ST-type connector) fiber ports.
10/100BaseT(X) Ethernet Port Connection
The 10/100BaseT(X) ports located on EDS’s front panel are used to
connect to Ethernet-enabled devices.
Below we show pinouts for both MDI (NIC-type) ports and MDI-X
(HUB/Switch-type) ports, and also show cable wiring diagrams for
straight-through and cross-over Ethernet cables.
10/100Base T(x) RJ45 Pinouts
MDI Port Pinouts
MDI-X Port Pinouts
8-pin RJ45
Pin
Signal
1
Tx+
2
Tx-
3
Rx+
6
Rx-
Pin
Signal
1
Rx+
2
Rx-
3
Tx+
6
Tx-
RJ45 (8-pin) to RJ45 (8-pin) Straight-Through Cable Wiring