Installation Guide

- 20 -
LED
Color
St a t e
De scr ip tion
t op LED
Of f
When t he port is inact ive or link
down.
1 0 M /
1 0 0 M /
1 0 0 0 M
Copper
bot t om
LED
Am b er
On
When the port is act ive an d links
at 10/ 100Mbps.
Blin k ing
( 4 t im e s/ se c)
When the port s dat a is being
tr ansm itt ed at 10/ 100Mbps.
Of f
When t he port is inact ive or link
down.
1 0 0 M
Fib er LED
Gr ee n
On
When the port s dat a is being
tr ansm itt ed at 100Mbps.
Blin k ing
( 4 t im e s/ se c)
When t he port s dat a is being
tr ansm itt ed at 100Mbps.
Of f
When t he port is inact ive or link
down.
1 0 0 M /
1 0 0 0 M
( SFP
port)
Gr ee n
On
When the port is act ive an d links
at 1,000Mbps.
Blin k ing
( 4 t im e s/ se c)
When the port s dat a is being
tr ansm itt ed at 1,000Mbps.
Of f
When t he port is inact ive or link
down.
Am b er
On
When the port is act ive an d links
at 100Mbps.
Blin k ing
( 4 t im e s/ se c)
When the port s dat a is being
tr ansm itt ed at 100Mbps.
Of f
When t he port is inact ive or link
down.
Spe cificat ions
I nt e r fa ce
RJ45 Port s
10/ 100BaseT( X) or 10/ 100 / 1000BaseT( X)
Fiber Port s
100BaseFx
100/ 1000BaseSFP
Console Por t
RS-232 ( RJ45 )
But t on
Reset but t on
LED I ndicat or s
STATE ( S) , FAULT ( F), PWR1 ( P1) , PWR2 ( P2 ),
MSTR/ HEAD ( M/ H) , CPLR/ TAI L ( C/ T) , SYNC
Alarm Cont act 1 nor m ally open elect rom agnet ic relay out put with
curr ent carr ying capacit y of 1 A @ 24 VDC
Digit al I nput
1 isolat ed digit al input:
+ 13 t o + 30V for st at e 1
-30 t o + 3V for st ate 0
Max. in put cur rent : 8 m A
PoE
CAU TI ON : When it is necessary t o connect t he PoE ports of a Power
By pass ( - LVA) m odel t o a Pow er Boost ( - LVB) m odel wit hin the sam e
syst em , do not use t he sam e power supply t o pow er bot h m odels.
Tot al Power Budget
Pow er Bypass ( -LVA m odel) : 240 W @ 48 VDC
power input
Power Boost ( - LVB m odel) : 62 W @ 12 VDC, 150
W @ 24 VDC ( 12 0 W for - T m odel), 180 W @ 48
VDC
PoE Out put Volt age
55 VDC