- 21 -
PoE Output Pow er
15.4 W for t he 802.3af st andard, 30 W for t he
802.3at st andard, 36 W in high pow er m ode, 60 W
in 802.3bt st andard
PoE Output Current
350 m A for t he 8 02.3af st andard, 600 m A for t he
802.3at st andard, 1960 m A for t he 802.3bt
st andard
Overload Curr ent
Prot ect ion at Por t
Present
PoE Pinout Mode A: Pair 1,2 ( V+ ) ; Pair 3,6 ( V- )
Mode B: pair 4,5 (V+ ) ; pair 7 ,8 (V-)
Pow e r
Pre- inst alled Power
Module
-LV/ -LV- T m odels: PWR- 100–LV
-HV/ -HV- T m odels: PWR- 105-HV-I
-LVA/ - LVA- T m odels: PWR-101- LV-BP-I
-LVB/ -LVB- T m odels: PWR-103- LV-VB- I
Not e
The EDS- 4008 Series support s m odular pow er
supplies. The m odel nam es and pow er param et er s
are det erm ined by the installed power m odule.
For ex am ple:
EDS- 4008- T + PWR- 100- LV = EDS- 4008- LV- T
EDS- 4008- T + PWR- 105- HV- I = EDS- 4008- HV- T
I f y ou install a differ ent pow er m odule, refer t o t he
specificat ions of t he corr espondin g m odel. For
exam ple, if y ou r eplace the power m odule of t he
EDS- 4008- LV- T with t he PWR-105 -HV- I , r efer t o
t he specificat ions of t he EDS-4008 -HV- T.
Rat ed Volt age
-LV/ -LV- T m odels: 12/ 24/ 48 VDC, r edundant dual
input s
-HV/ -HV- T m odels: 110/ 220 VDC/ VAC, single input
-LVA/ - LVA- T m odels: 48 VDC, redundant dual
input s
-LVB/ -LVB- T m odels: 12/ 24/ 48 VDC, redundant
dual input s
Operat ing Voltage
-LV/ -LV-T m odels: 9.6 to 60 VDC
-HV/ -HV- T m odels: 88 t o 300 VDC, 85 t o 264 VAC
-LVA/ - LVA- T m odels: 44 t o 57 VDC ( > 52 VDC for
PoE+ out put recom m ended)
-LVB/ -LVB- T m odels: 12 t o 57 VDC ( > 52 VDC for
PoE+ out put recom m ended)
Rat ed Current
-LV/ -LV-T m odels: 12- 48 VDC, 1. 50- 0.40 A or 24
VDC, 0.70 A
-HV/ -HV- T m odels: 110- 220 VAC, 50- 60 Hz, 0.30 -
0.20 A or 110- 220 VDC, 0.30- 0.20 A
-LVA/ - LVA- T m odels: 48 VDC, 5.42 A
-LVB/ -LVB- T m odels: 12/ 48 VDC, 7.46/ 4.27 A or
24 VDC, 7.26 A
Power
Consum pt ion
EDS- 4008- LV( - T) m odels: 7.20 W
EDS- 4008- HV( - T) m odels: 8.13 W
EDS- 4008- 2MST- LV( - T) models: 8.45 W
EDS- 4008- 2MST- HV( -T) m odels: 11.13 W
EDS- 4008- 2MSC- LV( - T) m odels: 8.45 W
EDS- 4008- 2MSC- HV( - T) m odels: 11.09 W
EDS- 4008- 2SSC- LV( -T) m odels: 8.98 W
EDS- 4008- 2SSC- HV( - T) m odels: 11.37 W