Installation guide

- 17 -
Turbo Ring V2DIP Switch Settings
DIP 1 DIP 2 DIP 3 DIP 4
ON: Enables the
default “Ring
Coupling
(backup)port.
ON: Enables this
EDS as the Ring
Master.
ON: Enables the
default “Ring
Coupling” port.
ON: Activates
DIP switches 1,
2, 3 to configure
“Turbo Ring V2
settings.
OFF: Enables the
default “Ring
Coupling
(primary)port.
OFF: This EDS
will not be the
Ring Master.
OFF: Do not use
this EDS as a ring
coupler.
OFF: DIP
switches 1, 2, 3
will be disabled.
NOTE You must enable the Turbo Ring function first before using the
DIP switch to activate the Master and Coupler functions.
NOTE If you do not enable any of the EDS-600 switches to be the Ring
Master, the Turbo Ring protocol will automatically choose the
EDS-600 with the smallest MAC address range to be the Ring
Master. If you accidentally enable more than one EDS-
600 to be
the Ring Master, these EDS-600 switches will auto-negotiate to
determine which one will be the Ring Master.
LED Indicators
The front panel of the EDS-600 contains several LED indicators. The
function of each LED is described in the following table:
LED Color State Description
Main System
PWR1 AMBER On Power is being supplied to power input
PWR1.
Off Power is not being supplied to power
input PWR1.
PWR2 AMBER On Power is being supplied to power input
PWR2.
Off Power is not being supplied to power
input PWR2.
FAULT RED On When the corresponding PORT alarm is
enabled, and a user-configured event is
triggered.
Off When the corresponding PORT alarm is
enabled and a user-configured event is
not triggered, or when the
corresponding PORT alarm is disabled.
MSTR/
HEAD
GREEN On When the EDS-600 is set as the Master
of the Turbo Ring or is set as the Head
of the Turbo Chain.
Blinking When the EDS-600 is set as the Ring
Master of the Turbo Ring or as the Head
of the Turbo Chain and the Turbo Ring
or Turbo Chain is down.