Installation guide

- 19 -
Digital Input Two inputs with the same ground, but
electrically isolated from the electronics
• For state “1”: +13 to +30 V
• For state “0”: -30 to +3 V
• Max. input current: 8 mA
Power
Input Voltage 12/24/48 VDC, redundant inputs
Input Current (@24V) EDS-608: 0.16A
EDS-611: 0.31A
EDS-616: 0.25A
EDS-619: 0.31A
Connection Two removable 5-pin and 6-pin terminal blocks
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Mechanical
Casing IP30 protection, metal case
Dimensions (W × H × D)
EDS-608/611:
124.9 x 151 x 157.2 mm (4.92 x 5.95 x 6.19 in)
EDS-616/619:
185 x 151 x 157.2 mm (7.28 x 5.95 x 6.19 in)
Weight EDS-608: 2.08 kg
EDS-611: 2.26 kg
EDS-616: 2.78 kg
EDS-619: 2.95 kg
Installation DIN-Rail, Wall Mounting Kit (optional kit) ,
Anti-Vibration Wiring Kit (optional)
Environment
Operating Temperature
0 to 60°C (32 to 140°F), standard models
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature -40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety UL 508, EN60950-1
Hazardous Location UL/cUL Class I, Division 2, Groups A, B, C, and
D; ATEX Zone 2, Ex nC nL IIC T4
EMI FCC Part 15, EN61000-6-4
EMS EN61000-6-2
EN61000-4-2 (ESD),
> level 2 for multi-mode models with ST
connectors
> level 3 for all other models
EN61000-4-3 (RS), Level 3
EN61000-4-4 (EFT), Level 2
EN61000-4-5 (Surge), Level 3
EN61000-4-6 (CS), Level 3
EN61000-4-8
EN61000-4-12
EN61000-4-29
Maritime DNV, GL, ABS, LR, NKK
Rail Traffic EN50121-4
Shock IEC60068-2-27
Free Fall IEC60068-2-32