User Manual
- 13 -
Power Requirements
Input Voltage
12/24/48 VDC, redundant inputs, Class 2
Input Current
0.16 A @ 24 VDC
Connection
One removable 6-pin terminal block
Overload Current
Protection
Present
Reverse Polarity
Protection
Present
Physical Characteristics
Housing
IP30 protection, metal case
Dimensions
29 x 135 x 105 mm (1.14 x 5.31 x 4.13 in)
Weight
290 g
Installation
DIN rail, wall mounting (optional kit)
Environmental Limits
Operating Temperature -10 to 60°C (14 to 140°F)
-40 to 75°C (-40 to 167°F) for -T models
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
Safety
UL 508
Hazardous Location
UL/cUL Class I, Division 2, Groups A, B, C, and
D; ATEX Zone 2, Ex nA nC IIC T4 Gc
EMI
FCC Part 15, CISPR (EN 55032) Class A
EMS
EN 61000-4-2 (ESD), Level 3
EN 61000-4-3 (RS), Level 3
EN 61000-4-4 (EFT), Level 3
EN 61000-4-5 (Surge), Level 3
EN 61000-4-6 (CS), Level 3
EN 61000-4-8
Rail Traffic
EN 50121-4
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Warranty
Warranty Period
5 years
Details
See www.moxa.com/warranty