Moxa EtherDevice Switch & PoE Splitter EDS-P308 Series & SPL-24 Hardware Installation Guide Second Edition, June 2008 © 2008 Moxa Inc., all rights reserved. Reproduction without permission is prohibited.
Overview We describe two products in this manual: The Moxa EtherDevice™ EDS-P308 Series is an 8-port smart Ethernet switch that provides an economical solution for your Ethernet connections. The switch supports PoE (Power-over-Ethernet) on ports 1 to 4, which means that the EDS-P308 Series can double as a piece of power source equipment (PSE). When used in this way, the EDS-P308 Series can supply up to 15.4 watts of power per port, and can power IEEE 802.
Wiring Requirements WARNING Do not disconnect modules or wires unless the power supply has been switched off or the area is known to be non-hazardous. The devices may only be connected to the supply voltage shown on the type plate. The devices are designed for operation with a Safety Extra-Low Voltage. Thus, they may only be connected to the supply voltage connections and to the signal contact with the Safety Extra-Low Voltages (SELV) in compliance with IEC 60950-1/EN 60950-1.
Package Checklist for EDS-P308 Series The Moxa EDS-P308 Series is shipped with the following items. If any of these items is missing or damaged, please contact your customer service representative for assistance. y y y y Moxa EtherDevice™ Switch EDS-P308 Hardware Installation Guide Moxa Product Warranty Statement Protective caps for unused ports Features of EDS-P308 Series High Performance Network Switching Technology y 10/100BaseT(X) (RJ45) y 100BaseFX (SC type, Multi/Single mode) y IEEE802.3/802.3u/802.
Fiber Ports LED Indicators DIP Switch Alarm Contact Power Input Voltage Input Current Connection Overload Current Protection Reverse Polarity Protection PoE (per port) Minimum output voltage Maximum output current Inrush current Overload detection Output current in short circuit condition Overload and short circuit time limit Turn off time Turn off voltage Maximum Output Power Mechanical Casing Dimensions Weight Installation Environmental Operating Temperature mode, and auto MDI/MDI-X connection 100BaseFX
Shock Freefall Vibration WARRANTY EN61000-4-11 IEC60068-2-27 IEC60068-2-32 IEC60068-2-6 5 years EDS-P308 Series Panel Layout 1. 2. Top Panel View 1 3. 4. 5. 6. 7. 8. 9. 10. 11. 12. 13. 14.
EDS-P308 (SC-type) Panel Layout EDS-P308-M-SC Front Panel View EDS-P308-MM-SC Front Panel View 2 2 5 6 7 12 9 5 6 7 9 16 12 16 8 8 10 10 11 13 13 11 Product models not shown here: EDS-P308-S-SC is identical to EDS-P308-M-SC. EDS-P308-SS-SC is identical to EDS-P308-MM-SC. Top Panel View 1 2 3 1 2 ON 3 4 4 5 6 8 DIP 7 Rear Panel View 2 1 14 15 14 1. Grounding screw 2. Terminal block for power inputs PWR1, PWR2 and relay output 3. Heat dissipation orifices 4. DIP switches 5.
Mounting Dimensions (unit = mm) 30.00 9.00 15.10 19.80 13.10 25.40 135.00 135.00 35.00 DlN-Rail DlN-Rail Kit 105.00 Front View 3.5 Side View 6 18.2 + + 18 10 10 5 13 46.77 27.20 48.30 39.37 13 13.9 57.05 25.71 13.9 66.80 6 23.15 DlN-Rail Kit + + 7.75 30.50 7.75 53.60 Rear View Wall Mounting Kit DIN-Rail Mounting The aluminum DIN-Rail attachment plate should already be fixed to the back panel of the EDS-P308 Series when you take it out of the box.
Wall Mounting (optional) For some applications, you will find it convenient to mount EDS-P308 Series on the wall, as illustrated below. STEP 1: Remove the aluminum DIN-Rail attachment plate from the EDS-P308’s rear panel, and then attach the wall mount plates, as shown in the diagram below. top plate ⇒ bottom plate STEP 2: Mounting the EDS-P308 on the wall requires 4 screws. Use the switch, with wall mount plates attached, as a guide to mark the correct locations of the 4 screws.
EDS-P308 Series’s Redundant Power Inputs Both power inputs can be connected simultaneously to live DC power sources. If one power source fails, the other live source acts as a backup, and automatically supplies all of EDS-P308 Series’s power needs. Wiring the Redundant Power Inputs The top two contacts and the bottom two contacts of the 6-contact terminal block connector on EDS’s top panel are used for EDS’s two DC inputs. Top and front views of one of the terminal block connectors are shown here.
EDS-P308 Series’s DIP Switch Settings ON 1 2 ON: Enables the corresponding PORT Alarm. If the port’s link fails, the relay will form an open circuit and the fault LED will light up. Off: Disables the corresponding PORT Alarm. The relay will form a closed circuit and the Fault LED will never light up. DIP 3 4 5 6 7 8 Wiring the Alarm Contact The alarm contact consists of the two middle contacts of the terminal block on EDS’s top panel.
LED Indicators The front panel of the EDS-P308 Series contains several LED indicators. The function of each LED is described in the table below. LED PWR1 PWR2 FAULT 10M 100M FX PoE Color State On Off Power is not being supplied to power input PWR1 On Power is being supplied to power input PWR2 Off Power is not being supplied to power input PWR2 On When the corresponding PORT alarm is enabled, and the port’s link is inactive.
Features of SPL-24 High Performance Network Switching Technology y IEEE802.3af compliance y Power/data split from PoE lines using either spare-pairs or data pairs y Support for up to 12.95W at 24 VDC y Support for up to 15.
Hazardous Location EMI EMS Shock Freefall Vibration WARRANTY UL/cUL Class I, Division 2, Groups A, B, C and D (pending) ATEX Class I, Zone 2, EEx nC IIC (pending) FCC Part 15, CISPR (EN55022) class A EN61000-4-2 (ESD), Level 3 EN61000-4-3 (RS), Level 3 EN61000-4-4 (EFT), Level 3 EN61000-4-5 (Surge), Level 3 EN61000-4-6 (CS), Level 3 IEC60068-2-27 IEC60068-2-32 IEC60068-2-6 5 years SLP-24 Panel Layout Top View Front View Rear View 2 1 3 4 P DATA OUT 2 V+ 5 OUTPUT : 24 VDC 7 PoE IN 6 1. 2.
Mounting Dimensions (unit = mm) 74 15 32 10.5 24.87 P 74 V+ 100 76.2 100 DATA OUT OUTPUT : 24 VDC PoE IN 86.5 24.87 Side View Front View Rear View Top View DIN-Rail Mounting for SPL-24 The plastic DIN-Rail attachment plate should already be fixed to the back panel of SPL-24 when you take it out of the box. If you need to reattach the DIN-Rail attachment plate, make sure the stiff metal spring is situated towards the top, as shown in the figures below.
Grounding the SPL-24 Grounding and wire routing help limit the effects of noise due to electromagnetic interference (EMI). Run the right most contact of the 3-contact terminal block to the grounding surface prior to connecting devices. Top View Front View ATTENTION This product is intended to be mounted to a well-grounded mounting surface, such as a metal panel.