EDS-P510 Series Featured Functions
3-5
Name
Setting Description Factory Default
Max. 63 Characters Specify an alias for each port, and assist the administrator in
remembering important information about the port.
E.g., PLC 1
None
Speed
Setting Description Factory Default
Auto Allows the port to use the IEEE 802.3u protocol to negotiate
with connected devices. The port and connected devices will
determine the best speed for that connection.
100M-Full
100M-Half
10M-Full
10M-Half
Choose one of these fixed speed options if the opposing
Ethernet device has trouble auto-negotiating line speed.
Auto
FDX Flow Ctrl
Setting Description Factory Default
Enable Enables flow control for this port when in auto-negotiate mode. Disable
Disable Disables flow control for this port when in auto-negotiate mode.
This setting enables or disables the flow control capability of this port when the “port transmission speed”
setting is in “auto” mode. The final result will be determined by the “auto” process between the EDS-P510
and connected devices.
MDI/MDIX
Setting Description Factory Default
Auto Allows the port to auto detect the port type of the opposing
Ethernet device and change the port type accordingly.
MDI
MDIX
Choose the MDI or MDIX option if the opposing Ethernet device
has trouble auto-negotiating port type.
Auto
Network
The Network configuration allows users to configure both IPv4 and IPv6 parameters for management access
over the network. The EDS-P510 series supports both IPv4 and IPv6, and can be managed through either of
these address types.
IPv4
The IPv4 settings include the switch’s IP address and subnet mask, as well as the IP address of the default
gateway. In addition, input cells are provided for the IP addresses of a 1st and 2nd DNS server.
IPv6
IPv6 setting includes two distinct address types—Link-Local Unicast address and Global Unicast address. A
Link-Local address makes the switch accessible over IPv6 for all devices attached to the same local subnet. To
connect to a larger network with multiple segments, the switch must be configured with a Global Unicast
address.