User`s manual
EDS-P510 Series Featured Functions
3-8
Current Date
Setting Description Factory Default
User adjustable date. The date parameter allows configuration of the local date in
yyyy/mm/dd format.
None
(yyyy/mm/dd)
Daylight Saving Time
Daylight saving time (also know as DST or summer time) involves advancing clocks (usually 1 hour) during
the summer time to provide an extra hour of daylight in the afternoon.
Start Date
Setting Description Factory Default
User adjustable date. The Start Date parameter allows users to enter the date that
daylight saving time begins.
None
End Date
Setting Description Factory Default
User adjustable date. The End Date parameter allows users to enter the date that
daylight saving time ends.
None
Offset
Setting Description Factory Default
User adjustable hour. The offset parameter indicates how many hours forward the
clock should be advanced.
None
System Up Time
Indicates the EDS-P510’s up time from the last cold start. The unit is seconds.
Time Zone
Setting Description Factory Default
User selectable time
zone
The time zone setting allows conversion from GMT (Greenwich
Mean Time) to local time.
GMT (Greenwich
Mean Time)
NOTE Changing the time zone will automatically correct the current time. You
should configure the time zone before
setting the time.
Time Server IP/Name
Setting Description Factory Default
1st Time Server
IP/Name
IP or Domain address (e.g., 192.168.1.1 or
time.stdtime.gov.tw or time.nist.gov).
2nd Time Server
IP/Name
The EDS-P510 will try to locate the 2nd NTP Server if the 1st
NTP Server fails to connect.
None
Time Server Query Period
Setting Description Factory Default
Query Period This parameter determines how frequently the time is updated
from the NTP server.
600 seconds