User`s manual
EDS-P510 Series Featured Functions
3-63
DI1 (OnOff) Digital Input 1 is triggered by on to off transition
DI1 (OffOn) Digital Input 1 is triggered by off to on transition
DI2 (OnOff) Digital Input 2 is triggered by on to off transition
DI2 (OffOn) Digital Input 2 is triggered by off to on transition
Configuration Change Activated A configuration item has been changed.
Authentication Failure An incorrect password is entered.
Comm. Redundancy Topology Changed Spanning Tree Protocol switches have changed their position
(applies only to the root of the tree).
The Master of the Turbo Ring has changed or the backup path is
activated.
Port Events Warning e-mail is sent when…
Link-ON The port is connected to another device.
Link-OFF The port is disconnected (e.g., the cable is pulled out, or the
opposing device shuts down).
Traffic-Overload The port’s traffic surpasses the Traffic-Threshold for that port
(provided this item is Enabled).
Traffic-Threshold (%) Enter a non-zero number if the port’s Traffic-Overload item is
Enabled.
Traffic-Duration (sec.) A Traffic-Overload warning is sent every Traffic-Duration seconds
if the average Traffic-Threshold is surpassed during that time
period.
NOTE The Traffic-Overload, Traffic-Threshold (%), and Traffic-Duration (sec.) Port Event items are related. If you
Enable the Traffic-Overload event, then be sure to enter a non-zero Traffic-
T
hreshold percentage, as well as
a Traffic-Duration between 1 and 300 seconds.
NOTE Warning e-mail messages will have the sender field formatted in the form:
Moxa_EtherDevice_Switch_0001@Switch_Location
where Moxa_EtherDevice_Switch is the default Switch Name, 0001 is the EDS-P510’s serial number, and
Switch_Location is the default Server Location.
Refer to the Basic Settings section to see how to modify Switch Name and Switch Location.
Email Setup