User`s manual

EDS-P510 Series Featured Functions
3-75
Syslog Server 1
Setting Description Factory Default
IP Address Enter the IP address of 1st Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 1st Syslog Server. 514
Syslog Server 2
Setting Description Factory Default
IP Address Enter the IP address of 2nd Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 2nd Syslog Server. 514
Syslog Server 3
Setting Description Factory Default
IP Address Enter the IP address of 3rd Syslog Server used by your
network.
None
Port Destination
(1 to 65535)
Enter the UDP port of 3rd Syslog Server. 514
NOTE The following events will be recorded into the EDS-P510’s Event Log table, and will then be sent to the
specified Syslog Server:
1. Cold start
2. Warm start
3. Configuration change activated
4. Power 1/2 transition (Off ( On), Power 1/2 transition (On ( Off)
5. Authentication fail
6. Topology changed
7. Master setting is mismatched
8. DI 1/2 transition (Off ( On), DI 1/2 transition (On ( Off)
9. Port traffic overload
10. dot1x Auth Fail
11. Port link off / on
12. Power-Fail
13. PD-Failure
Using HTTPS/SSL
To secure your HTTP access, the EDS-P510 supports HTTPS/SSL to encrypt all HTTP traffic. Perform the
following steps to access the EDS-P510’s web browser interface via HTTPS/SSL.
1. Open Internet Explorer and type https://EDS-P510’s IP address in the address field. Press Enter to
establish the connection.