Installation Guide

- 13 -
Fiber Communication
Connector Type
ST (single-mode and multi-mode), 100Base-FX
Cable Requirements
9/125 μm (single-mode) or 62.5/125 μm (multi-
mode)
Wavelength 1310 nm (single-mode and mult i-mode)
Tx Power
> -5 dBm (single-mode) or > -20 dBm (multi-
mode)
Rx Range
-3 to -34 dBm (single-mode), -3 to -32 dBm
(multi-mode)
Environmental Limits
Operating
Temperature
0 to 60°C (32 to 140°F)
-40 to 7C (-40 to 167°F) for -T model
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Power
Input Power Voltage
12 to 48 VDC dual power input for redundancy
Relay Output
1 digital output relay to alarm (normal: closed)
with current-carrying capacity of 1 A @ 30 VDC
Mechanical Specifications
Dimensions
30.3 × 70 × 115 mm (1.19 × 2.76 × 4.53 in)
Material
Metal
Gross Weight
294 g (0.65 lb)
사용자안내문 (User Guide)
기기는 업무용 환경에서 사용할 목적으로 적합성평가를 받은
기기로서가정용 환경에서 사용하는 경우 전파간섭의 우려가 있습니다.
(This equipment has KC approval for use in industrial environments and
could possibly interfere with household equipment.)
종별
Type of Equipment
사용자안내문
User Guide
A 기기 (업무용 방송 통신기
자재)
Class A Equipment
(Broadcasting and
Communication Equipment for
Industrial and Commercial Use)
기기는 업무용 (A ) 전자파 적합
기기로서 판매자 또는 사용자는
점을 주의하시기 바라며 가정 외의
지역에서 사용하는 것을 목적으로
합니다.
This equipment is the EMC conformity
equipment (Class A) for I
ndustrial and
Commercial Use. The seller or user
should take note of this as this
equipment can be used in places that
exclude homes.