Make sure CAN high (CAN_H) is connected to the CAN high pin, and
CAN low (CAN_L) is connected to the CAN low pin of your CAN device.
Fiber Cable
ST-Port Pinouts
ST-Port to ST-Port Cable Wiring
ATTENTION
This is a Class 1 laser/LED product. Do not stare into the laser
beam
.
1. Ca
utionUse of the controls or adjustments or the
performance of procedures other than those specified herein
may result in hazardous radiation exposure."
2.
Complies with 21 CFR 1040.10 and1040.11, except for
co
nformance with IEC 60825-1 Ed. 3., as described in Laser
Notice No. 56, dated May 8, 2019.
Switch Settings
There are three DIP switches on the front panel of the ICF-1171I
Series; DIP switch 1 is reserved for future use. See the usage below.
Use DIP switch 3 to set up CAN (CAN 2.0) or CAN FD (ISO CAN FD)
mode. CAN in the table below is equal to CAN 2.0, and CAN FD is equal
to ISO CAN FD.
CAN Mode
Switch 3
CAN FD
ON
CAN
OFF (default)
Use DIP switch 2 to enable terminator.
120 Ω Terminator
Switch 2