User Manual

- 10 -
Power
Input Voltage
24/48 VDC (22 to 57 VDC), redundant dual
inputs
Input Current
2.71 A @24 VDC (with full 60 W PoE loading)
1.37 A @48 VDC (with full 60 W PoE loading)
Power Consumption
Max. 5.29 W (with full loading excluding PDs
consumption)
Inrush Current
15.64 A @ 48 VDC (0.1-1ms)
Electrical Isolation
2250 VDC to chassis for 60 s
Heat Dissipation
18.05 BTU/h
Overload Current
Protection at Input
Present
Reverse Polarity
Protection
Present
Connection
1 removable 4-contact terminal blocks
Mechanical
Housing
IP30 protection, metal case
Dimensions
115 × 30.3 × 78.8 mm (H x W x D)
Weight
245 g
Installation
DIN-Rail, wall mounting
Environmental Limits
Operating Temperature
Standard Models: 0 to 60°C (32 to 140°F)
Wide Temp. Models: -40 to 75°C (-40 to 167°F)
Storage Temperature
-40 to 85°C (-40 to 185°F)
Ambient Relative
Humidity
5 to 95% (non-condensing)
Regulatory Approvals
EMI
FCC Part 15, CISPR (EN 55032) class A
EMS EN 61000-4-2 (ESD), Level 3
EN 61000-4-3 (RS), Level 3
EN 61000-4-4 (EFT), Level 3
EN 61000-4-5 (Surge), Level 3
EN 61000-4-6 (CS), Level 3
EN 61000-4-8, Level 5
Shock
IEC 60068-2-27
Freefall
IEC 60068-2-32
Vibration
IEC 60068-2-6
Warranty
Time Period
5 years
Details
www.moxa.com/warranty
Patent http://www.moxa.com/doc/operations/Moxa_Patent_Marking.pdf