User Manual
Moxa’s Managed Switch Next Generation OS (v3.x) User Manual
174
Enable
Setting
Description
Factory Default
Enabled
Enable LLDP.
Disabled
Disabled
Disable LLDP.
LLDP Version
Setting
Description
Factory Default
Show the LLDP version
Show the LLDP version automatically.
2005
Transmit Interval (sec.)
Setting
Description
Factory Default
5 to 32768
Set the transmit interval of LLDP messages
30
Notification Interval (sec.)
Setting
Description
Factory Default
5 to 3600
Specify the notification interval.
5
Tx Delay (sec.)
Setting
Description
Factory Default
1 to 8192
Specify the Tx delay interval.
2
Reinitialization Delay (sec.)
Setting
Description
Factory Default
1 to 10
Specify the LLDP reinitialization delay interval.
2
Holdtime Multiplier
Setting
Description
Factory Default
2 to 10
Specify the holdtime multiplier value.
4
Chassis ID Subtype
Setting
Description
Factory Default
Chassis-Component
Select Chassis-Component as Chassis ID subtype.
Mac-Addr
If-Alias
Select If-Alias as Chassis ID subtype.
Port-Component
Select Port-Component as Chassis ID subtype.
MAC-Addr
Select MAC-Address as Chassis ID subtype.
Network Address
Select Network Address as Chassis ID subtype.
If-Name
Select If-Name as Chassis ID subtype.
Local
Select Local as Chassis ID subtype.
When finished, click APPLY to save your changes.
Each port for the LLDP settings can also be configured. Select the edit icon for the port you want to
configure.