Event Name
Severity
Event Description
Log capacity threshold Warning
Number of event log entries {{logEntryNum}} has
reached the threshold.
Log Turbo Chain Port Restart Notice
Port-Channel {{channel id}} has restarted by
Turbo Chain.
Port {{index}}/{{number}} has restarted by
Turbo Chain.
Login failed Warning
[Account {{user_name}}] log in failed via
{{interface}}.
Login lockout Warning
[Account {{user_name}}] locked due to
{{failed_times}} failed login attempts.
Login successful Notice
[Account {{user_name}}] successfully logged in
via {{interface}}.
Low input voltage Warning
The input voltage of the power supply has dropped
below 46 VDC. Please adjust the voltage to
between 46 and 57 VDC to fit the PoE voltage
requirement.
Master changed
Warning
Ring {{Index}} master has changed.
Master mismatch
Warning
Ring {{Index}} master setting does not match.
module change
Notice
M{{index}} module has changed.
Module Initialized Fail
Error
M{{index}} Module initialized has failed.
Module inserted
Notice
M{{Index}} Module inserted.
Module removed
Notice
M{{index}} Module removed.
MSTP new port role Warning
MSTP (MST{{Index}}) port {{number}} role
changed from {{role}} to {{role}}.
MSTP root changed Warning
MSTP (MST{{Index}}) new root has been elected
in topology.
MSTP topology changed Warning
Topology (MST{{Index}}) has been changed by
MSTP.
OSPF DR router adjacency changed Notice
Interface {{ip addr}}{{ip addr}}{{ip addr}}{{ip
addr}} DR neighbor {{ip addr}}{{ip addr}}{{ip
addr}}{{ip addr}}adjacency changed.
OSPF interface DR changed Notice
Interface {{ip addr}}{{ip addr}}{{ip addr}}{{ip
addr}} DR Change{{ip addr}}{{ip addr}}{{ip
addr}}{{ip addr}}to {{ip addr}}{{ip addr}}{{ip
addr}}{{ip addr}}.
OSPF interface ISM became DR Notice
Interface {{ip addr}{{ip addr}}{{ip addr}}{{ip
addr}} become DR.
Over power budget limit Warning
The consumed power {{power_value}} of all the
PDs have exceeded the maximum input power
{{input_power_value}}.
Packet dropped by Port Security Warning
Port {{index}}/{{number}} dropped packets due
to violation of Port Security rule.
Password changed Notice
Password of [Account: {{user_name}}] has been
changed.
PD no response Error
Port {{number}} device is not responding to the
PD failure check. Please check the device status.
PD over-current Error
Current of port {{number}} has exceeded the
safety limit. Please check the device status.
PD power off
Notice
Port {{number}} PD power off.
PD power on
Notice
Port {{number}} PD power on.
Port Link Down Notice
Port {{index}}/{{number}} link down.
Port-channel {{Channel id}} link down.
Port Link Up Notice
Port {{index}}/{{number}} link up.
Port-channel {{Channel id}} link up.
Port recovery by Rate Limit Warning
Port {{index}}/{{number}} has recovered by rate
limit.
Port shutdown by Loop Critical
Port {{index}}/{{number}} looping and
shutdown.
Port shutdown by Port Security Warning
Port {{index}}/{{number}} has shut down due to
a violation of the Port Security rule.