MGate 5103 Series
1-port Modbus RTU/ASCII/TCP/EtherNet/IP-to-PROFINET gateways
Features and Benefits
• Converts Modbus, or EtherNet/IP to PROFINET
• Supports PROFINET IO device
• Supports Modbus RTU/ASCII/TCP master/client and slave/server
• Supports EtherNet/IP Adapter
• Effortless configuration via web-based wizard
• Built-in Ethernet cascading for easy wiring
• Embedded traffic monitoring/diagnostic information for easy troubleshooting
• microSD card for configuration backup/duplication and event logs
• Status monitoring and fault protection for easy maintenance
• Serial port with 2 kV isolation protection
• -40 to 75°C wide operating temperature models available
• Supports redundant dual DC power inputs and 1 relay output
• Security features based on IEC 62443
Certifications
Introduction
The MGate 5103 is an industrial Ethernet gateway for converting Modbus RTU/ASCII/TCP or EtherNet/IP to PROFINET-based network
communications. To integrate existing Modbus devices onto a PROFINET network, use the MGate 5103 as a Modbus master/slave or EtherNet/IP
adapter to collect data and exchange data with PROFINET devices. The latest exchange data will be stored in the gateway. The gateway will
convert stored Modbus or EtherNet/IP data into PROFINET packets so the PROFINET IO Controller can control or monitor field devices.
Easy Configuration via Web Console
The MGate 5103 Series comes with an illustrated Quick Setup guide designed to make configuration easy. With Quick Setup, you can easily access
protocol conversion modes and finish the configuration in a few steps. The MGate 5103 Series also supports a GSDML export function. GSDML
files can be imported into PROFINET PLCs to save time on PLC configuration.
Modbus RTU/ASCII/TCP Protocol Traffic Monitor
MGate 5103 gateways support Modbus RTU/ASCII/TCP Protocol Traffic Monitor for easy troubleshooting, especially during the installation stage.
Communication issues could be caused by incorrect software parameters, such as slave IDs and register addresses, that were entered incorrectly,
or an incorrect command configuration. With Modbus RTU/ASCII/TCP Protocol Traffic Monitor, you can check the captured data and easily identify
the root cause.
Maintenance Functions
MGate 5103 gateways support a system log function that records events in the MGate; users can easily review log data remotely through the web
console. The gateways also support status monitoring and fault protection functions. The status monitoring function notifies a PLC/DCS/SCADA
system when a Modbus device gets disconnected or does not respond, in which case the process PLC/DCS gets the status of each end device
and then issues alarms to notify operators.
Specifications
Ethernet Interface
10/100BaseT(X) Ports (RJ45 connector) 2
Auto MDI/MDI-X connection
Magnetic Isolation Protection 1.5 kV (built-in)