User manual

NPort 5000AI-M12 Series Web Console Configuration
5-16
RFC2217 Mode
TCP alive check time
Setting Factory Default Necessity
0 to 99 min 7 min Optional
0 min: TCP connection is not closed due to an idle TCP connection.
1 to 99 min: The NPort 5000AI-M12 automatically closes the TCP connection if there is no TCP activity for the
given time. After the connection is closed, the NPort 5000AI-M12 starts listening for another hosts TCP
connection.
Local TCP port
Setting Factory Default Necessity
1 to 65535 4001 Required
The Local TCP port is the TCP port that the NPort 5000AI-M12 uses to listen to connections, and that other
devices must use to contact the NPort 5000AI-M12. To avoid conflicts with well known TCP ports, the default
is set to 4001.
Packing length
Setting Factory Default Necessity
0 to 1024 0 Optional
Default = 0: The Delimiter Process will be followed, regardless of the length of the data packet. If the data
length (in bytes) matches the configured value, the data will be forced out. The data length can be configured
for 0 to 1024 bytes. Set to 0 if you do not need to limit the length.
Delimiter 1
Setting Factory Default Necessity
00 to FF None Optional
Delimiter 2
Setting Factory Default Necessity
00 to FF None Optional