Datasheet

www.moxa.com
3
Serial Interface
Connector NPort 6600 Series: 8-pin RJ45
NPort 6450 Series: DB9 male
No. of Ports NPort 6450 Series: 4
NPort 6600-8 Series: 8
NPort 6600-16 Series: 16
NPort 6600-32 Series: 32
Serial Standards NPort 6610 Series: RS-232
NPort 6450/6650 Series: RS-232, RS-422, RS-485
Secure Operation Modes Reverse SSH, Secure Pair Connection, Secure Real COM, Secure TCP Client, Secure
TCP Server, SSH
Standard Operation Modes Disabled, Ethernet Modem, Pair Connection, PPP, Printer, Real COM, Reverse Telnet,
RFC2217, TCP Client, TCP Server, Terminal, UDP
Baudrate 50 bps to 921.6 kbps (supports non-standard baudrates)
Console Port NPort 6600 Series: RS-232 (TxD, RxD, GND), 8-pin RJ45 (19200, n, 8, 1)
Data Bits 5, 6, 7, 8
Stop Bits 1, 1.5, 2
Parity None, Even, Odd, Space, Mark
Flow Control RTS/CTS, DTR/DSR, XON/XOFF
Pull High/Low Resistor for RS-485 1 kilo-ohm, 150 kilo-ohms
RS-485 Data Direction Control ADDC® (automatic data direction control)
Terminator for RS-485 NPort 6600 Series: 120 ohms
Serial Signals
RS-232 TxD, RxD, RTS, CTS, DTR, DSR, DCD, GND
RS-422 Tx+, Tx-, Rx+, Rx-, GND
RS-485-4w Tx+, Tx-, Rx+, Rx-, GND
RS-485-2w Data+, Data-, GND
Power Parameters
Input Current NPort 6450 Series: 730 mA @ 12 VDC
NPort 6600 Series
DC Models: 293 mA @ 48 VDC, 200 mA @ 88 VDC
AC Models: 140 mA @ 100 VAC (8 ports), 192 mA @ 100 VAC (16 ports), 285 mA @ 100
VAC (32 ports)
Input Voltage NPort 6450 Series: 12 to 48 VDC
NPort 6600 Series
AC Models: 100 to 240 VAC
DC Models: ±48 VDC (20 to 72 VDC, -20 to -72 VDC), 110 VDC (88 to 300 VDC)
Reliability
Automatic Reboot Trigger Built-in WDT
Alert Tools Built-in buzzer and RTC (real-time clock)