User`s manual
Table Of Contents
- 1. Introduction
- 2. Getting Started
- 3. Initial IP Address Configuration
- 4. Web Console Configuration
- 5. System Management Settings
- 6. Introduction and Configuring VPN
- 7. Configuring OnCell Central Management Software
- 8. OnCell Search Utility
- A. Default Settings
- B. Dynamic Domain Name Server
- C. Auto IP Report Protocol

OnCell 5000 Series Introduction
1-6
Cellular Interface (OnCell 5004/5104-HSDPA-JPS/JPN)
Standards: UMTS/HSDPA
Band Options: 2100 MHz
Tx Power: UMTS/HSDPA: 0.25 W
WAN Interface
Number of Ports: 1
Ethernet: 10/100 Mbps, RJ45 connector, Auto MDI/MDIX
Magnetic Isolation Protection: 1.5 KV built-in
LAN Interface
Number of Ports: 4
Ethernet: 10/100 Mbps, RJ45 connector, auto MDI/MDIX
Magnetic Isolation Protection: 1.5 KV built-in
SIM Interface
Number of SIMs: 2
SIM Control: 3 V
I/O Interface (OnCell 5104-HSDPA)
Alarm Contact: 1 relay output with current carrying capacity of 1 A @ 24 VDC
Digital Inputs: 2 electrically isolated inputs
• +13 to +30 V for state “1” (On)
• +3 to -30 V for state “0” (Off)
Software
Network Protocols: UDP/TCP, SNTP, ICMP, DDNS, DHCP/BOOTP, PPPoE, PPP, DNS Relay, HTTPS, Telnet,
IPSec
Router/Firewall: NAT, port forwarding, static routing
Authentication: Local user-name and password
Security: IP filtering
Management Software
OnCell Central Manager: Centralized management solution for accessing private IPs from the Internet
Physical Characteristics
Housing: Aluminum, providing IP30 protection
Weight:
OnCell 5004-HSDPA, OnCell 5004-HSDPA-JPS: 505±5 g
OnCell 5104-HSDPA, OnCell 5104-HSDPA-JPS: 645±5 g
Dimensions:
OnCell 5004-HSDPA, OnCell 5004-HSDPA-JPS: 158 x 103 x 34 mm (6.22 x 4.06 x 1.34 in)
OnCell 5104-HSDPA, OnCell 5104-HSDPA-JPS: 135 x 103 x 50.8 mm (5.32 x 4.06 x 2.00 in)
Environmental Limits
Operating Temperature: -30 to 55°C (-22 to 131°F)
Operating Humidity: 5 to 95% RH
Storage Temperature: -40 to 75°C (-40 to 167°F)
Power Requirements
Number of Power Inputs: 1 terminal block, 1 power jack
Input Voltage: 12 to 48 VDC
Data Link:
OnCell 5004-HSDPA, OnCell 5004-HSDPA-JPS: 900 mA (peak) @ 12 V
OnCell 5104-HSDPA, OnCell 5104-HSDPA-JPS: 950 mA (peak) @ 12 V