OnCell G3111/G3151/G3211/G3251 Series User’s Manual System Management Settings
12-6
Group Event
System
System Cold Start, System Warm Start, Power 1 DOWN, Power 2 DOWN,
Cell. module awake/fail, Cell. module close/over temperature range
Network
DHCP/BOOTP Get IP/Renew, NTP, Mail Fail, NTP Connect Fail, IP Conflict,
Network Link Down, Cell. module get/lost IP
Config
Login Fail, IP Changed, Password Changed, Config Changed, Firmware
Upgrade, SSL Key Import, Config Import, Config Export
OpMode Connect, Disconnect, Restart
Auto Warning Settings
Event Settings
On the Event Settings page, you may configure how administrators are notified of certain system,
network, configuration, and cellular module events. Depending on the event, different options for
automatic notification are available, as shown above. Mail refers to sending an e-mail to a
specified address. Trap refers to sending an SNMP Trap. SMS refers to sending a message to a
specified phone number.
Cold start: This refers to starting the system from a power off state, or after upgrading your
firmware
Warm start: This refers to restarting the OnCell G3111/G3151/G3211/G3251 without turning the
power off.
Network Event: These settings configure the OnCell to change the status of the relay output and
SMS if the specified connection goes down.
Console (web/text) login auth fail: This field refers to a failed attempt to log in to a password
protected OnCell G3111/G3151/G3211/G3251 console.
IP changed: With this IP address change, the OnCell G3111/G3151/G3211/G3251 will send and
email or SMS warning after it reboots.