OnCell G3111/G3151/G3211/G3251 Series User’s Manual System Management Settings
12-8
communication equipment is powered down. When the DSR signal changes to low, the OnCell
G3111/G3151/G3211/G3251 will automatically send a warning to the administrator as configured
on the Serial Event Settings page.
For relay output function, after the relay output status has been changed, administrators may reset
its status by selecting Acknowledge Event from the OnCell G3111/G3151/G3211/G3251 console,
or by correcting the DSR signal. Please refer to the section on System Monitoring later in this
chapter for more information.
ATTENTION
SNMP indicates a change in DCD or DSR signals but does not differentiate between the two. A
change in either signal from “–to “+” is indicated by link upand a change in either signal
from “+” to “–” is indicated by link down.
E-mail Alert
The E-mail Alert settings determine how e-mail warnings are sent for system and serial port events.
You may configure up to 4 e-mail addresses to receive automatic warnings.
ATTENTION
Consult your Network Administrator or ISP for the proper mail server settings. The Auto warning
function may not work properly if it is not configured correctly. The OnCell
G3111/G3151/G3211/G3251s SMTP AUTH supports LOGIN, PLAIN, and CRAM-MD5 (RFC
2554).
Mail server: This field is for your mail servers domain name or IP address.
User name: This field is for your mail servers user name, if required.
Password: This field is for your mail servers password, if required.
From e-mail address: This is the e-mail address from which automatic e-mail warnings will be
sent.
To e-mail address 1 to 4: This is the e-mail address or addresses to which the automatic e-mail
warnings will be sent.