OnCell G3111/G3151/G3211/G3251 Series User’s Manual Using the Web Console
6-6
page of basic settings that you can configure.
You must click on the Submit button to keep your configuration changes. The Submit button will
be located at the bottom of every page that has configurable settings. If you navigate to another page
without clicking the Submit button, your settings will not be retained.
Changes will not take effect until they are saved and the OnCell is restarted! You may complete
this in one step by clicking on the Save/Restart option after you submit a change. If you need to
make several changes before restarting, you may save your changes without restarting by selecting
Save Configuration in the navigation panel. If you restart the OnCell G3111/G3151/G3211/G3251
without saving your configuration, the OnCell G3111/G3151/G3211/G3251 will discard all
submitted changes.
Basic Settings
The Basic Settings screen can be accessed from the navigation panel.
Server Settings
Server name: This is an optional free text field for your own use; it does not affect the operation of
the OnCell G3111/G3151/G3211/G3251, and can be used to help differentiate one OnCell
G3111/G3151/G3211/G3251 server from another.
Server location: This is an optional free text field for your own use; it does not affect the operation
of the OnCell G3111/G3151/G3211/G3251, and is useful for assigning or describing the location of
an OnCell G3111/G3151/G3211/G3251. In a network environment of multiple servers, this can be a
valuable aid when doing maintenance.
Time Settings
The OnCell G3111/G3151/G3211/G3251 has a built-in Real-Time Clock for time calibration
functions. Functions such as Auto Warning Email or SNMP Trap can add real-time information to
messages.
Before making any adjustments to the time, first select the correct time zone and submit the
change. The console will display the real time according to the time zone. To modify the real time
clock, click on Modify next to the Local time field. Once you submit the new time, the OnCell
G3111/G3151/G3211/G3251’s firmware will modify the GMT time according to your time zone
and local time settings.