Reset Button
The button labeled Reset returns the UC-8410/8416/8418 to its factory default configuration.
Press the Reset button continuously for at least 5 seconds to load the factory default
configuration. After the factory default configuration has been loaded, the system will reboot
automatically. The Ready LED will blink on and off for the first 5 seconds, and then maintain a
steady glow once the system has rebooted.
We recommend that you only use this function if the software is not working properly and you
want to load factory default settings. To reset an embedded Linux system, always use the software
reboot command />reboot to protect the integrity of data being transmitted or processed.
ATTENTION
Reset button preserves user’s data
The Reset button will NOT format the user directory and erase the user’s data. Pressing the
Reset button will only load the configuration file. All files in the /etc, /home and /tmp
directories will revert to their factory defaults, but other user data will still exist in the Flash
ROM.
Real Time Clock
The UC-8410/8416/8418’s real time clock is powered by a lithium battery. We strongly
recommend that you do not replace the lithium battery without help from a qualified Moxa support
engineer. If you need to change the battery, contact the Moxa RMA service team.
WARNING
There is a risk of explosion if the battery is replaced by an incorrect type.