User's Manual

UC-8100A-ME-T Series Hardware Introduction
1-4
Environmental Limits
Operating Temperature:
Without LTE Module preinstalled: -40 to 85°C (-40 to 185°F)
With LTE Module preinstalled: -40 to 70°C (-40 to 158°F)
Storage Temperature: -40 to 85°C (-40 to 185°F)
Ambient Relative Humidity: 5 to 95% (non-condensing)
Anti-Vibration: 2 Grms @ IEC 60068-2-64, random wave, 5-500 Hz, 1 hr per axis (without any USB devices
attached)
Anti-Shock: 20 g @ IEC 60068-2-27, half sine wave, 30 ms
Power Requirements
Input Voltage: 12 to 36 VDC (3-pin terminal block, V+, V-, SG)
Input Current: 500 mA @ 12 VDC
Power Consumption: 6 W (without cellular module and external USB device attached)
Standards and Certifications
Safety: UL 60950-1
Hazardous Location: C1D2, IECEx, ATEX
EMC:EN 55032/24, KC, BSMI, RCM, EAC
EMI: CISPR 32, FCC Part 15B Class A
EMS:IEC 61000-4-2 ESD: Contact: 8 kV; Air: 15 kV
IEC 61000-4-3 RS: 80 MHz to 1 GHz, 20 V/m
IEC 61000-4-4 EFT: Power: 4 kV; Signal: 4 kV
IEC 61000-4-5 Surge: DC Power: 1 kV; Signal: 1 kV
IEC 61000-4-6 CS: 10 V
IEC 61000-4-8 PFMF: 300 A/m, 60 s
Green Product: RoHS, CRoHS, WEEE
RF Regulatory: FCC, PTCRB, IC, CE RED (EN 301489, EN 301511, EN 301908), NCC, RCM
Carrier Approval: Verizon, Telus, AT&T
Reliability
Alert Tools: External RTC (real-time clock)
Automatic Reboot Trigger: External WDT (watchdog timer)
Warranty
Warranty Period: 5 years
Details: See www.moxa.com/warranty