User Manual

AirWorks AWK-3131A Web Console Configuration
3-33
E-mail Server Settings
You can set up to 4 e-mail addresses to receive alarm emails from the AWK-3131A. The following parameters
can be configured on the E-mail Server Settings page. In addition, a Send Test Mail button can be used to
test whether the Mail server and e-mail addresses work well. More detailed explanations about these
parameters are given after the following figure.
Mail server (SMTP)
Setting Description Factory Default
IP address The IP Address of your email server. None
User name & Password
Setting Description Factory Default
User name and password used in the SMTP server None
From e-mail address
Setting Description Factory Default
Max. 63 characters Enter the administrators e-mail address which will be shown in
the Fromfield of a warning e-mail.
None
To E-mail address 1/ 2/ 3/ 4
Setting Description Factory Default
Max. 63 characters Enter the receivers’ e-mail addresses. None
Relay
The AWK-3131A has one relay output, which consists of 2 terminal block contacts on the AWK-3131As top
panel. These relay contacts are used to indicate user-configured events and system failure.
The two wires attached to the relay contacts form an open circuit when a user-configured event is triggered. If
a user-configured event does not occur, the relay circuit will remain closed. For safety reasons, the relay circuit
is kept open when the AWK-3131A is not powered.
Relay Event Types
You can check the box for Active to enable the event items. All default values are deactivated (unchecked).
Details for each event item can be found in the System log Event Typestable on page 3-31.