User Manual

AirWorks AWK-3131A Web Console Configuration
Time Settings
The AWK-3131A has a time calibration function based on information from an NTP server or user specified
Date and Time information. Functions such as Auto warning can add real-time information to the message.
The Current local time shows the AWK-3131A’s system time when you open this web page. You can click
on the Set Time button to activate the updated date and time parameters. An “(Updated)” string will
appear to indicate that the change is complete. Local time settings will be immediately activated in the
system without running Save and Restart.
NOTE The AWK-3131A has a built-in real time clock (RTC). We strongly recommend that users update the Local
time for the AWK-3131A after the initial setup or a long-term shutdown, especially when the network does
not have an Internet connection for accessing the NTP server or there is no NTP server on the LAN.
Current local time
Setting Description Factory Default
User adjustable time The date and time parameters allow configuration of the local None
time, with immediate activation.
Use 24-hour format: yyyy/mm/dd hh:mm:ss
Time zone
Setting Description Factory Default
User selectable time The time zone setting allows conversion from GMT (Greenwich GMT (Greenwich
zone Mean Time) to local time. Mean Time)
ATTENTION
Changing the time zone will automatically adjust the Current local time. You should configure the Time
zone before setting the Current local time.
Daylight saving time
Setting Description Factory Default
Enable/ Disable Daylight saving time (also know as DST or summer time) Disable
involves advancing clocks (usually 1 hour) during the summer
time to provide an extra hour of daylight in the afternoon.
When Daylight saving time is enabled, the following parameters will be shown:
Starts at: The date that daylight saving time begins.
Stops at: The date that daylight saving time ends.
Time offset: Indicates how many hours forward the clock should be advanced.