Multicast Rate
Setting Description
Factory Default
Available rates You can set a fixed multicast rate for the transmission of
6M
broadcast and multicast packets on a per-radio basis. This
parameter can be useful in an environment where multicast
video streaming is occurring in the wireless medium, providing
the wireless clients are capable of handling the configured rate
Guarding Interval
Setting Description
Factory Default
Guarding Interval Guarding interval is used to ensure that distinct transmissions
800ns.
do not interfere with one another. You can select the guarding
interval manually for Wireless-N connections. The two options
are Short (400ns) and Long (800ns).
Transmission Power
Setting Description
Factory Default
Available power Users can manually select a target power to mask max output 10
power. Because different transmission rate would have it own
max output power, please reference product datasheet.
For 802.11bg, the available setting is from 0 to 20
Beacon Interval (for AP/Master mode only)
Setting Description
Factory Default
Beacon Interval Indicates the frequency interval of the beacon
100 (ms)
(40 to 1000 ms)
DTIM Interval (for AP/Master mode only)
Setting Description
Factory Default
Data Beacon Rate Indicates how often the AWK-3131A sends out a Delivery
1
(1 to 15) Traffic Indication Message
Fragmentation threshold
Setting Description
Factory Default
Fragment Length Specifies the maximum size a data packet before splitting and
2346
(256 to 2346) creating another new packet
RTS threshold
Setting Description
Factory Default
RTS/CTS Threshold Determines how large a packet can be before the Access Point
2346
(256 to 2346) coordinates transmission and reception to ensure efficient
communication
NOTE You can refer to the related glossaries in Chapter 5 for detailed information about the above-mentioned settings. By
setting these parameters properly, you can better tune the performance of your wireless network.
Transmission distance (for 802.11a/n only)
Setting Description Factory Default
Distance or max. range
Specifies the transmission distance or max. range between two
500
for transmission
AWK devices. This parameter should be set properly, especially
(500 to 2500 m) for long-distance communication.
3-17